Taizhou MECO Refrigeration Equipment Co.,Ltd

Fan Coil Unit Expert! Focus to Professional!

Manufacturer from China
Active Member
7 Years
Home / Products / Cassette Fan Coil Unit /

400CFM 3.8Kw 1RT 4 Way Cassette Fan Cooling Unit

Contact Now
Taizhou MECO Refrigeration Equipment Co.,Ltd
City:taizhou
Province/State:zhejiang
Country/Region:china
Contact Person:MrSimon Liu
Contact Now

400CFM 3.8Kw 1RT 4 Way Cassette Fan Cooling Unit

Ask Latest Price
Brand Name :MECO
Model Number :MFP-68KM-(Q)MM1
Certification :CE, ISO, Rohs
Place of Origin :CHINA
MOQ :to be discussed
Price :USD
Payment Terms :T/T
Supply Ability :10000PCS/MONTH
Delivery Time :25DAYS
Packaging Details :STANDARD EXPORT CARTON
Cooling Capacity :3.8Kw
Heating Capacity :5.9Kw
Air Flow :400CFM
Motor Type :AC Motor
Display Type :Digital Display
Water Pump :Build In Water Pump
Electrical Box :Outside/Build In Optional
Fresh Air Hole :Standard Available
Power Supply :110/220V 1Ph 50/60Hz
Modbus :Optional
Auto Restart :Optional
Finger Protect :Finger Protect Grill Optional
Drain Tray :Extra Bigger Drain Tray Optional
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

M style CE certified Hydronic cassette fan coil unit with build in water pump capacity 400CFM

Specifications for hydronic four way cassette fan coil model MFP-68KM-(Q)MM1:

1. Air flow 400CFM,680CMH

2. Cooling capacity 3800W

3. Heating capacty 5900W

4. Two pipe/tube system

5. With build in water pump

6. Power supply 220V-1-50Hz/60Hz

7. Unit size 592*592*342mm

Cassette Type FCU Model No.
2 pipe system MFP-68KM-(Q)MM1 220V-1-50Hz/60Hz
Cooling Capacity
Testing item Capacity-W At Fan speed Air Volume CMH
Total Capacity 【w】 3800 High Speed 680
Sensible Capacity【w】 2850
Total Capacity 【w】 3250 Medium Speed 540
Sensible Capacity【w】 2350
Total Capacity 【w】 2600 Low Speed 410
Sensible Capacity【w】 1850
Heating Capacity
Testing item Capacity-W At Fan speed Air Volume CMH
Total Capacity 【w】 5900 High Speed 680
Total Capacity 【w】 5000 Medium Speed 540
Total Capacity 【w】 3950 Low Speed 410
Entering air temperature Cooling Mode Entering air temperature2 Heating Mode
Dry ball Temp 【℃】 27.0 Dry ball Temp 【℃】 20
Wet ball Temp 【℃】 19.5
Inlet water temp 【℃】 7.0 Inlet water temp 【℃】 50
Outlet water temp 【℃】 12.0 Outlet water temp 【℃】 40
Item data Item2 Data2
Rated Power input 【 w】 40.0 Unit dimension L【mm】 592
waterflow volume 【m3/h】 0.34 Unit dimension W【mm】 592
water pressure dropping 【kPa】 11.0 Unit dimension H【mm】 242
Connection pipe Dia【Inch】 ZG3/4" Panel dimension L【mm】 650
Static pressure【Pa】 0.0 Panel dimension W【mm】 650
Water drain pipe Dia 【mm】 ¢26 Panel dimension H【mm】 40
Packing data
Unit dimension L【mm】 710 Panel dimension L【mm】 710
Unit dimension W【mm】 690 Panel dimension W【mm】 710
Unit dimension H【mm】 275 Panel dimension H【mm】 80
Loading QTY 40HQ/40GP/20GP 370/320/160 PCS

Operating limits Water inlet temperature: 5-80°C.
Room air temperature: 6-40°C.
Relative humidity: 15-75%.
Maximum exchanger pressure: 800 kPa (81,5 mc.a.).
Power supply voltage: 230 V ±10%.

Full ranges of capacities we have for M style cassette fan coil unit:

MODEL air volume COOLING CAPACITY HEATING CAPACITY POWER INPUT
m3/h W W W
MFP-34KM-Q1M 380 2000 3100 40
MFP-51KM-Q1M 550 3000 4700 50
MFP-68KM-Q1M 680 3800 5900 58
MFP-80KM-Q1M 780 4200 6500 60
MFP-85KM-Q1M 880 4900 7600 70
MFP-102KM-Q1M 1050 5800 9000 95
MFP-130KM-Q1M 1300 7000 10900 125
MFP-136KM-Q1M 1380 7500 11600 130
MFP-153KM-Q1M 1550 8100 12200 145
MFP-170KM-Q1M 1750 9800 15200 160
MFP-204KM-Q1M 2050 11000 17100 190
MFP-238KM-Q1M 2200 12000 18600 210
MFP-272KM-Q1M 2720 15000 24000 230

Testing condition:

2-tube system 4-tube system

Cooling

Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC

Entering/out water temperature: 7ºC/ 12℃

Cooling

Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC

Entering/out water temperature: 7ºC/ 12ºC

Heating

Entering air temperature: 20ºC

Entering water temperature: 60ºC, Same water flow rate as for the cooling

Heating

Entering air temperature: 20ºC

Entering/out water temperature: 60ºC/ 50ºC

Notes:

1. Both AC or BLDC motor available.

2. Both 50HZ or 60HZ power supplies available.


M style Cassette fan coil unit introduction

As we all know Hydronic cassette units are ideal for applications and modernizations with suspended ceilings. Ceiling cassette fan coil units make each served area an independent controlled temperature zone to suit diverse requirements. Such as hotels, offices, restaurant, shopping mall applications,etc.

MECO start to produce the first cassette fan coil unit in 2001, and Cassette fan coil unit always a hard point for us.

After nearly 20 years’ experience accumulation, we have completely models of M style cassette fan coil unit and BLDC motor type cassette fan coil unit. The M style cassette fan coil unit is our core competitiveness which has high stability and comprehensive functions.


Performance Features for M style chilled water Cassette fan coil Units.

    Inquiry Cart 0